Overview

The Cisco UCS C220 M6 server is a one-rack unit server that can be used standalone, or as part of the Cisco Unified Computing System, which unifies computing, networking, management, virtualization, and storage access into a single integrated architecture. Cisco UCS also enables end-to-end server visibility, management, and control in both bare metal and virtualized environments. Each Cisco UCS C220 M6 server supports:

  • a maximum of two 3rd Generation Intel Xeon processors.

  • 32 DDR4 DIMMs (16 per CPU) for a total system memory of either 8 TB (32 256 GB DDR4 DIMMs) or 12 TB (16 x 256 GB DDR4 DIMMs1 and 16 x 512 GB Intel® Optane™ Persistent Memory Module.

    (PMEMs)).

  • 3 PCI Express riser connectors, which provide slots for “full height” and “half height” PCI-e adapters.

  • Two Titanium (80 PLUS rated) power supplies with support for N and N+1 power redundancy modes.

  • 2 10GBase-T Ethernet LAN over Motherboard (LOM) ports for network connectivity, plus one 1 Gigabit Ethernet dedicated management port

  • One mLOM/VIC card provides 10G/25G/40G/50G/100G/200G connectivity. Supported cards are:

    • Cisco UCS VIC 15428 Quad Port CNA MLOM (UCSC-M-V5Q50G) supports:

      • a x16 PCIe Gen4 Host Interface to the rack server

      • four 10G/25G/50G SFP56 ports

      • 4GB DDR4 Memory, 3200 MHz

      • Integrated blower for optimal ventilation

    • Cisco UCS VIC 15427 Quad Port CNA MLOM (UCSC-M-V5Q50GV2) supports:

      • a x16 PCIe Gen4 Host Interface to the rack server

      • four 10G/25G/50G SFP+/SFP28/SFP56 ports

      • 4GB DDR4 Memory, 3200 MHz

      • Integrated blower for optimal ventilation

      • Secure boot support

    • Cisco UCS VIC 15425 Quad Port 10G/25G/50G SFP56 CNA PCIe (UCSC-P-V5Q50G)

      • a x16 PCIe Gen4 Host Interface to the rack server

      • Four 10G/25G/50G SFP+/SFP28/SFP56 ports

      • 4GB DDR4 Memory, 3200MHz

      • Integrated blower for optimal ventilation

      • Secure boot support

    • Cisco UCS VIC 15238 Dual Port 40G/100G/200G QSFP56 mLOM (UCSC-M-V5D200G) supports:

      • a x16 PCIe Gen4 Host Interface to the rack server

      • two 40G/100G/200G QSFP/QSFP28/QSFP56 ports

      • 4GB DDR4 Memory, 3200 MHz

      • Integrated blower for optimal ventilation

    • Cisco UCS VIC 15237 Dual Port 40G/100G/200G QSFP56 mLOM (UCSC-M-V5D200GV2) supports:

      • a x16 PCIe Gen4 Host Interface to the rack server

      • two 40G/100G/200G QSFP/QSFP28/QSFP56 ports

      • 4GB DDR4 Memory, 3200 MHz

      • Integrated blower for optimal ventilation

      • Secure boot support

    • Cisco UCS VIC 15235 Dual Port 40G/100G/200G QSFP56 CNA PCIe (UCSC-P-V5D200GV2)

      • a x16 PCIe Gen4 Host Interface to the rack server

      • two 40G/100G/200G QSFP/QSFP28/QSFP56 ports

      • 4GB DDR4 Memory, 3200MHz

      • Integrated blower for optimal ventilation

      • Secure boot support

    • Cisco UCS VIC 1495 Dual Port 40/100G/200G half-height QSFP28 CNA PCIe (UCSC-PCIE-C100-04) supports:

      • a x16 PCIe Gen3 Host Interface to the rack server

      • two 40G/100G QSFP/QSFP28 ports

      • 2GB DDR3 Memory, 1866 MHz

    • Cisco UCS VIC 1477 Dual Port 40/100G QSFP28 mLOM (UCSC-M-V100-04)

      • a x16 PCIe Gen3 Host Interface to the rack server

      • two 40G/100G QSFP28 ports

      • 2GB DDR3 Memory, 1866 MHz

    • Cisco UCS VIC 1467 Quad Port 10/25G SFP28 mLOM (UCSC-M-V25-04) supports:

      • a x16 PCIe Gen3 Host Interface to the rack server

      • four 10G/25G SFP28 ports

      • 2GB DDR3 Memory, 1866 MHz

    • Cisco UCS VIC 1455 Quad Port 10G/25G half-height SFP28 CNA PCIe (UCSC-PCIE-C25Q-04) supports:

      • a x16 PCIe Gen3 Host Interface to the rack server

      • four 10G/25G SFP/SFP28 ports providing two 50G fabric connections

      • 2GB DDR3 Memory, 1866 MHz

  • One KVM port on the front of the server.

  • Two different front-loading hardware configurations are available:

    • The Cisco UCS C220 M6 SFF (UCSC-C220-M6S): This model supports only small form-factor (SFF) drives and has a 10-drive backplane. Supports up to 10 front-loading 2.5-inch SAS/SATA drives, and up to 4 of the drives can be NVMe.

    • The Cisco UCS C220 M6 NVMe (UCSC-C220-M6N): This model supports only small form-factor (SFF) drives and has a 10-drive backplane. Supports up to 10 front-loading 2.5-inch NVMe-only SSDs.

  • Rear PCI risers are supported as one to three half-height PCIe risers, or one to two full-height PCIe risers.

  • The server provides an internal slot for one of the following:

    • SATA Interposer to control SATA drives from the PCH (AHCI), or

    • Cisco 12G RAID controller with cache backup to control SAS/SATA drives, or

    • Cisco 12G SAS pass-through HBA to control SAS/SATA drives

External Features

This topic shows the external features of the server versions.

Cisco UCS C220 M6 Server Front Panel Features

The following figure shows the front panel features of the small form-factor drive versions of the server.

For definitions of LED states, see Front-Panel LEDs.

Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (1)

1

Drive bays 1 – 10 support SAS/SATA hard disk drives (HDDs) and solid-state drives (SSDs). As an option, drive bays 1-4 can contain up to 4 NVMe drives in any number up to 4. Drive bays 5 through 10 support only SAS/SATA HDDs or SSDs.

NVMe drives are supported in a dual CPU server only.

2

Unit identification button/LED

3

Power button/power status LED

4

KVM connector

(used with KVM cable that provides one DB-15 VGA, one DB-9 serial, and two USB 2.0 connectors)

5

System LED cluster:

  • Fan status LED

  • System status LED

  • Power supply status LED

  • Network link activity LED

  • Temperature status LED

For more information, see Front-Panel LEDs

-

Cisco UCS C220 M6 Server Rear Panel Features

The rear panel features can be different depending on the number and type of PCIe cards in the server.

By default, single CPU servers come with only one half-height riser 1 installed, and dual CPU servers support all three half-height risers.

Rear PCIe risers can be one of the following configurations:

  • Half-height risers:

    • one half-height, ¾ length riser (not shown). With this configuration, PCIe slot (slot 1) supports one half-height, ¾ length, x16 lanes PCIe card and is controlled by CPU 1.

    • three half-height, ¾ length risers. See "UCS C220 M6 Server Rear Panel, Half Height, ¾ Length PCIe Cards" below.

  • Full-height risers: Two full height, ¾ length risers. See "Cisco UCS C220 M6 Server Rear Panel, Full Height, ¾ Length PCIe Cards" below.

Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (2)

Note

For definitions of LED states, see Rear-Panel LEDs.

Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (3)

1

PCIe slots, three

This configuration accepts three card in riser slots 1, 2, and 3 as follows:

  • Riser 1, which is controlled by CPU 1:

    • Supports one PCIe slot (slot 1)

    • Slot 1 is half-height, 3/4 length, x16

  • Riser 2, which is controlled by CPU 1:

    • Supports one PCIe slot (slot 2)

    • Slot 2 is half-height, 3/4 length, x16

  • Riser 3, which is controlled by CPU 2:

    • Supports one PCIe slot (slot 3)

    • Slot 3 is half-height, 3/4 length, x16

2

Power supply units (PSUs), two which can be redundant when configured in 1+1 power mode.

3

Modular LAN-on-motherboard (mLOM) card bay (x16 PCIe lane)

USB 3.0 ports (two)

4

System identification button/LED

5

USB 3.0 ports (two)

6

Dual 1-Gb/10-Gb Ethernet ports (LAN1 and LAN2)

The dual LAN ports can support 1 Gbps and 10 Gbps, depending on the link partner capability.

7

1-Gb Ethernet dedicated management port

8

COM port (RJ-45 connector)

9

VGA video port (DB-15 connector)

Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (4)

1

PCIe slots, two

This configuration accepts two cards in riser slots 1 and 2 as follows:

  • Riser 1, which is controlled by CPU 1:

    • Plugs into riser 1 motherboard connector

    • Supports one full-height, 3/4 length, x16 PCIe card

  • Riser 2, which is controlled by CPU 2:

    • Plugs into riser 3 motherboard connector

    • Supports one full-height, 3/4 length, x16 PCIe card

2

Power supply units (PSUs), two which can be redundant when configured in 1+1 power mode.

3

Modular LAN-on-motherboard (mLOM) card bay (x16 PCIe lane)

4

Unit identification button/LED

5

USB 3.0 ports (two)

6

Dual 1-Gb/10-Gb Ethernet ports (LAN1 and LAN2)

The dual LAN ports can support 1 Gbps and 10 Gbps, depending on the link partner capability.

7

1-Gb Ethernet dedicated management port

8

COM port (RJ-45 connector)

9

VGA video port (DB-15 connector)

Serviceable Component Locations

This topic shows the locations of the field-replaceable components and service-related items. The view in the following figure shows the server with the top cover removed.

Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (5)
Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (6)

Note

The chassis has an internal USB drive under the

1

Front-loading drive bays 1–10 support SAS/SATA drives.

2

M6 modular RAID card or SATA Interposer card

3

Cooling fan modules, eight.

Each fan is hot-swappable

4

SuperCap module mounting bracket

The SuperCap module (not shown) that mounts into this location provides RAID write-cache backup.

5

DIMM sockets on motherboard, 32 total, 16 per CPU

Eight DIMM sockets are placed between the CPUs and the server sidewall, and 16 DIMM sockets are placed between the two CPUs.

6

Motherboard CPU socket two (CPU2)

7

M.2 module connector

Supports a boot-optimized RAID controller with connectors for up to two SATA M.2 SSDs

8

Power Supply Units (PSUs), two

9

PCIe riser slot 2

Accepts 1 full height, full width PCIe riser card.

Includes PCIe cable connectors for front-loading NVMe SSDs (x8 lane)

10

PCIe riser slot 1

Accepts 1 full height, full width (x16 lane) PCIe riser card

Note

The chassis supports an internal USB drive (not shown) at this PCIe slot. See Replacing a USB Drive.

11

Modular LOM (mLOM) card bay on chassis floor (x16 PCIe lane)

The mLOM card bay sits below PCIe riser slot 1.

12

Motherboard CPU socket one (CPU1)

13

Front Panel Controller board

The view in the following figure shows the individual component locations and numbering, including the FHFW PCIe cards.Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (7)

Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (8)

1

Front-loading drive bays 1–10 support SAS/SATA drives.

2

M6 modular RAID card or SATA Interposer card

3

Cooling fan modules, eight.

Each fan is hot-swappable

4

SuperCap module mounting bracket

The SuperCap module (not shown) that mounts into this location provides RAID write-cache backup.

5

DIMM sockets on motherboard, 32 total, 16 per CPU

Eight DIMM sockets are placed between the CPUs and the server sidewall, and 16 DIMM sockets are placed between the two CPUs.

6

Motherboard CPU socket

CPU2 is the top socket.

7

M.2 module connector

Supports a boot-optimized RAID controller with connectors for up to two SATA M.2 SSDs

8

Power Supply Units (PSUs), two

9

PCIe riser slot 3

Accepts 1 half height, half width PCIe riser card.

10

PCIe riser slot 2

Accepts 1 half height, half width PCIe riser card.

11

PCIe riser slot 1

Accepts 1 half height, half width PCIe riser card

Note

The chassis supports an internal USB drive (not shown) at this PCIe slot. See Replacing a USB Drive.

12

Modular LOM (mLOM) card bay on chassis floor (x16 PCIe lane)

The mLOM card bay sits below PCIe riser slot 1.

13

Motherboard CPU socket

CPU1 is the bottom socket

14

Front Panel Controller board

The view in the following figure shows the individual component locations and numbering, including the HHHL PCIe slots.Cisco UCS C220 M6 Server Installation and Service Guide - Overview [Cisco UCS C220 M6 Rack Server] (9)

The Technical Specifications Sheets for all versions of this server, which include supported component part numbers, are at Cisco UCS Servers Technical Specifications Sheets (scroll down to Technical Specifications).

Summary of Server Features

The following table lists a summary of server features.

Feature

Description

Chassis

One rack-unit (1RU) chassis

Central Processor

Up to two 3rd Generation Intel Xeon processors.

Memory

32 slots for registered DIMMs (RDIMMs), DDR4 DIMMs, 3DS DIMMs, and load-reduced DIMMs (LR DIMMs) up to 3200 MHz. Also supported is Intel® Optane™ Persistent Memory Modules (PMEMs)

Multi-bit error protection

This server supports multi-bit error protection.

Video

The Cisco Integrated Management Controller (CIMC) provides video using the Matrox G200e video/graphics controller:

  • Integrated 2D graphics core with hardware acceleration

  • DDR3 memory interface supports up to 512 MB of addressable memory (8 MB is allocated by default to video memory)

  • Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz

  • High-speed integrated 24-bit RAMDAC

  • Single lane PCI-Express host interface running at Gen 2 speed

Network and management I/O

Rear panel:

  • One 1-Gb Ethernet dedicated management port (RJ-45 connector)

  • Two 1-Gb/10-Gb BASE-T Ethernet LAN ports (RJ-45 connectors)

    The dual LAN ports can support 10 Gbps, 1 Gbps, 100 Mbps, or 10 Mbps. The LAN ports autonegotiate to the correct link speed based on the link partner capability.

  • One RS-232 serial port (RJ-45 connector)

  • One VGA video connector port (DB-15 connector)

  • Two USB 3.0 ports

Front panel:

  • One front-panel keyboard/video/mouse (KVM) connector that is used with the KVM breakout cable. The breakout cable provides two USB 2.0, one VGA, and one DB-9 serial connector.

Modular LOM

One dedicated socket (x16 PCIe lane) that can be used to add an mLOM card for additional rear-panel connectivity. As an optional hardware configuration, the Cisco CNIC mLOM module supports two 100G QSFP+ ports or 4 25 Gbps Ethernet ports.

Power

Up to two of the following hot-swappable power supplies:

  • 1050 W (AC)

  • 1050 W (DC)

  • 1600 W (AC)

  • 2300 W (AC)

One power supply is mandatory; one more can be added for 1 + 1 redundancy.

ACPI

The advanced configuration and power interface (ACPI) 4.0 standard is supported.

Front Panel

The front panel provides status indications and control buttons

Cooling

Eight hot-swappable fan modules for front-to-rear cooling.

InfiniBand

In addition to Fibre Channel, Ethernet and other industry-standards, the PCI slots in this server support the InfiniBand architecture up HDR IB (200Gbps).

Expansion Slots

Three half-height riser slots

  • Riser 1 (controlled by CPU 1): One x16 PCIe Gen4 Slot, (Cisco VIC), half-height, 3/4 length

  • Riser 2 (controlled by CPU 1): One x16 PCIe Gen4 Slot, half-height, 3/4 length

  • Riser 3 (controlled by CPU 2): One x16 PCIe Gen4 Slot, (Cisco VIC), half-height, 3/4 length

Two full-height riser slots

  • Riser 1 (controlled by CPU 1): One x16 PCIe Gen4 Slot,, full-height, 3/4 length

  • Riser 2 (controlled by CPU 2): One x16 PCIe Gen4 Slot, full-height, 3/4 length

Interfaces

Rear panel:

  • One 1Gbase-T RJ-45 management port

  • Two 10Gbase-T LOM ports

  • One RS-232 serial port (RJ45 connector)

  • One DB15 VGA connector

  • Two USB 3.0 port connectors

  • One flexible modular LAN on motherboard (mLOM) slot that can accommodate various interface cards

Front panel:

  • One KVM console connector, which supplies the pins for a KVM break out cable that supports the following:

    • Two USB 2.0 connectors

    • One VGA DB15 video connector

    • One serial port (RS232) RJ45 connector

Integrated Management Processor

Baseboard Management Controller (BMC) running Cisco Integrated Management Controller (CIMC) firmware.

Depending on your CIMC settings, the CIMC can be accessed through the 1GE dedicated management port, the 1GE/10GE LOM ports, or a Cisco virtual interface card (VIC).

CIMC supports managing the entire server platform, as well providing management capabilities for various individual subsystems and components, such as PSUs, Cisco VIC, GPUs, MRAID and HBA storage controllers, and so on.

Storage Controllers

The SATA Interposer board, Cisco 12G SAS RAID Controller with 4GB FBWC, or Cisco 12G SAS HBA. Only one of these at a time can be used.

A Cisco 9500-8e 12G SAS HBA can be plugged into available PCIe risers for external JBOD attach. This HBA can be used at the same time as one of the other storage controllers.

  • SATA Interposer board: AHCI support of up to eight SATA-only drives (slots 1-4 and 6-9 only)

  • Cisco 12G RAID controller

    • RAID support (RAID 0, 1, 5, 6, 10) and SRAID0

    • Supports up to 10 front-loading SFF drives

  • Cisco 12G SAS HBA

    • No RAID support

    • JBOD/Pass-through Mode support

    • Supports up to 10 SFF front-loading SAS/SATA drives

  • Cisco 12G 9500-8e SAS HBA

    • No RAID support

    • Supports external JBOD attach (supports up to 1024 SAS/SATA devices or 32 NVMe devices)

    • Plugs into an appropriate PCIe riser slot (up to two supported)

For a detailed list of storage controller options, see Supported Storage Controllers and Cables.

Modular LAN over Motherboard (mLOM) slot

The dedicated mLOM slot on the motherboard can flexibly accommodate Cisco Virtual Interface Cards (VICs).

UCSM

Unified Computing System Manager (UCSM) runs in the Fabric Interconnect and automatically discovers and provisions some of the server components.

Cisco UCS C220 M6 Server Installation and Service Guide  - Overview [Cisco UCS C220 M6 Rack Server] (2024)

FAQs

How do I access my Cisco UCS server? ›

In the Login dialog box, do the following:
  1. Enter your username and password.
  2. If the Cisco UCS instance implements domains, select the appropriate domain from the Domain drop-down list.
  3. Click Login.

What is the use of Cisco UCS server? ›

Cisco UCS S-Series Storage Servers are modular servers that support more than a petabyte of internal storage to support storage-intensive workloads including big data, content streaming, online backup, and storage-as-a-service applications.

What is the difference between Cisco UCS blade and rack? ›

The primary difference between blade and rack servers is their design. Blade servers are modular and designed with a circuit board that shares multiple components like CPU, memory, storage, et cetera. On the other hand, rack servers have a bigger form factor as they have more architecture components.

How to reboot server in Cisco UCS? ›

Resetting a Blade Server
  1. In the Navigation pane, click the Equipment tab.
  2. On the Equipment tab, expand Equipment > Chassis > Chassis Number > Servers.
  3. Choose the server that you want to reset.
  4. In the Work pane, click the General tab.
  5. In the Actions area, click Reset.
  6. In the Reset Server dialog box, do the following:

What is the default username and password for Cisco UCS server? ›

Each Cisco UCS instance has a default user account, admin, which cannot be modified or deleted. This account is the system administrator or superuser account and has full privileges. There is no default password assigned to the admin account; you must choose the password during the initial system setup.

How to configure IP address in Cisco UCS server? ›

How do you change the IP Address of the Cisco UCS Manager?
  1. Log into the UCS manager.
  2. On the left hand side is a person silhouette with a gear. ...
  3. Under the General tab in the main screen there is Actions and then Management Interfaces. ...
  4. Change the Virtual IP address.
Sep 16, 2020

What are the different kinds of UCS servers available? ›

Cisco UCS servers are available in two categories: Blade Servers (B series) and rack mount servers (C Series). Both flavors are designed using same industry-standard components like Intel Xeon CPU.

What does UCS stand for in Cisco? ›

Cisco Servers - Unified Computing System (UCS) - Cisco.

What ports are required for Cisco UCS? ›

TCP and UDP Ports
PortInterfaceUsage
443Static HTMLCisco UCS Manager login page access
80Static HTMLClient download
443XMLCisco UCS Manager XML API access
80XMLPorts used by Cisco UCS Manager GUI and third party management stations.
11 more rows
Jan 7, 2023

What is the difference between a chassis and a server? ›

The chassis is the small outer case of one or more blade servers used to store the mechanical parts, including servers and racks. Blades. These small mechanical parts hold servers and contain the memory systems to store data and serve information to the computer systems in a network.

What is a rack server used for? ›

Virtualization: Rack servers can be used for virtualization, which allows multiple operating systems and applications to run on a single physical server. This can help organizations save on hardware costs and improve the efficiency of their computing infrastructure.

What is the difference between server rack and server cabinet? ›

Server racks and cabinets use accessories that host server and network equipment. For the most part, you can use the same internal accessories in a rack or a cabinet and both are available with casters. The primary difference between a server rack and a data center cabinet is that the cabinet is completely enclosed.

What is the boot menu key for Cisco UCS server? ›

Step 1 During startup, press F6 to enter the boot selection menu.

How do I remove or decommission a server in UCS? ›

Login to UCS and navigate to the affected server. 2. In the Actions pane, click Server Maintenance, Decommission. Click Ok, then Yes.

How do I access my Cisco phone web interface? ›

Enter the IP address of your desk phone in the address bar.

The web user interface of your desk phone will now show. Depending on your Cisco desk phone, the web user interface may have different tabs. : It is recommended to use browser such as Firefox or Microsoft Edge. Chrome will not load the phone's web interface.

How do I access my Cisco router web interface? ›

Open your browser and enter 192.168. 1.1in the address bar. The Login Screen appears. Enter the Username webui and the Password cisco.

Where does the Cisco UCS manager run? ›

Cisco UCS Manager is the management system for all components in a UCS Manager. Cisco UCS Manager runs within the fabric interconnect.

Top Articles
Latest Posts
Article information

Author: Kieth Sipes

Last Updated:

Views: 6454

Rating: 4.7 / 5 (67 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Kieth Sipes

Birthday: 2001-04-14

Address: Suite 492 62479 Champlin Loop, South Catrice, MS 57271

Phone: +9663362133320

Job: District Sales Analyst

Hobby: Digital arts, Dance, Ghost hunting, Worldbuilding, Kayaking, Table tennis, 3D printing

Introduction: My name is Kieth Sipes, I am a zany, rich, courageous, powerful, faithful, jolly, excited person who loves writing and wants to share my knowledge and understanding with you.